Generate Catalog For :

Single Beam UV VIS SpectrophotometerTRSUV-608

Download Catalog

Description :

Single Beam UV VIS Spectrophotometer TRSUV-608 is a small device with a 7-inch multi-color touch screen. It has an automatic wavelength range of 325 to 1100 nm as well as a bandwidth of 4 nm. Having patented technology that allows for simple and effective human-computer interaction with a clear display of test data It has a photometric range of 0.0 to 200.0 % T, -0.301 to 4.000A, and 0.000 to 9999 C with an accuracy of ± 0.5% T. It includes a sample compartment for 5 to 50 mm cuvettes.

Specification

Photometry

Single Beam

Monochromatic Type

Czerny-Turner

Focal Length

160 mm

Grating

1200 lines/mm

Detector

Silicon Photocell

Spectrum Bandwidth

4 nm

Wavelength Range

325 to 1100 nm

Wavelength Accuracy

± 1 nm

Wavelength Repeatability

≤ 0.5 nm

Photometric Range

0.0 to 200.0 % T -0.301 to 4.000 A 0.000 to 9999 C

Photometric Accuracy

± 0.3% T, ± 0.002Abs (0 to 0.5 A)


± 0.004Abs (0.5 to 1 A)

Photometric Repeatability

≤ 0.15% T, 0.001Abs (0 to 0.5 A)


0.002Abs (0.5 to 1 A)

Wavelength Scanning Speed

-

Baseline Flatness

-

Stray Light

≤ 0.1% T(measured at NaNO2 at 360 nm)

Noise

100%(T) noise ≤ 0.5% (T), 0% (T) noise ≤ 0.2% (T)

Baseline Drift

± 0.002 Abs / 30 mins ( 500nm after preheat warm up for 2 hours )

Power

AC220 V ± 22 V, 50Hz ± 1Hz, 100 W

Packing Size

630 mm×610 mm×500 mm

Weight

0.16m³, 25 Kg

Features

  • 7-inch multi-color touch screen and patented technology for simple and effective human-computer interaction with clear test data display
  • A built-in thermal printer for printing test results and facilitating the creation and storage of data reports
  • A USB communication port and UV professional data processing software enables data processing and mapping functions
  • The storage of large amounts of data files, and help customers with a second development
  • Sample compartment for 5 to 50mm cuvettes
  • Automatic wavelength selection, which is both quick and accurate
  • Scanning kinetic time scanning, automatic wavelength, linear regression, direct concentration readout, peak detection, regular printing, and so on
  • Power shutdown protection measures that are advanced to memorize detector data and regression
  • To achieve fast initialization, the equation and instrument correction parameters must be known ahead of time
  • Lifelong safety for tungsten and deuterium lamps

Application

It is being combined with an ARM processed core, has test speeds and functions possessed by high-end instruments. The instrument can meet the requirement of quantitative analysis for most samples conducted within the visible and ultraviolet-visible spectral range in conventional laboratories and is suitable for use in medicine and health, clinical examination, biochemical, petrochemical, environmental protection, quality control departments, colleges, and universities and others.